Application
" CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to
"95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4, GB14048-4.
Matched auxiliary contact type LA1-DN02(2NC), LA1-DN11(1NO+NC), LA1-DN20(2NO), LA1-DN22(2NO+2NC), LA1-DN40(4NO, LA1-DN04(4NC), LA1-DN13(1NO+3NC), LA1-DN31(3NO+1NC)
Matched time delay auxiliary contact type Time delay after power on: LA2-DT0(0.1-3S), LA2-DT2(0.1-30S), LA2-DT4(10-180S), Time delay after power off: LA3-DR0(0.1-3S), LA3-DR2(0.1-30S), LA3-DR4(10-180S).
" CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660V AC 50Hz or 60Hz, rated current up to
"95A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine- interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 60947-4, GB14048-4.
Matched auxiliary contact type LA1-DN02(2NC), LA1-DN11(1NO+NC), LA1-DN20(2NO), LA1-DN22(2NO+2NC), LA1-DN40(4NO, LA1-DN04(4NC), LA1-DN13(1NO+3NC), LA1-DN31(3NO+1NC)
Matched time delay auxiliary contact type Time delay after power on: LA2-DT0(0.1-3S), LA2-DT2(0.1-30S), LA2-DT4(10-180S), Time delay after power off: LA3-DR0(0.1-3S), LA3-DR2(0.1-30S), LA3-DR4(10-180S).
1.Specifications | |||||||||||
Type | CJX2-09 (LC1-D09) | CJX2-12 (LC1-D12) | CJX2-18 (LC1-D18) | CJX2-25 (LC1-D25) | CJX2-32 (LC1-D32) | CJX2-40 (LC1-D40) | CJX2-50 (LC1-D50) | CJX2-65 (LC1-D65) | CJX2-80 (LC1-D80) | CJX2-95 (LC1-D95) | |
Rated working current (A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | 80 | 95 |
AC4 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | 37 | 44 | |
AC3 capacity of three-phase squirrel-cage motor AC3(kW) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 25 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | |
415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | 45 | 45 | |
440V | 4 | 5.5 | 9 | 11 | 15 | 22 | 30 | 37 | 45 | 45 | |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | 55 | 55 | |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | 45 | 45 | |
Rated heat current (A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | 125 | 125 | |
Electrical life | AC4X104 | 20 | 20-15 | 41475 | 41470 | 41470 | 41554 | 7 | 41461 | 41460 | 41460 |
AC3X106 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1.6 | 1.6 | 1.6 | |
Mechanical lifeX106 | 20 | 20 | 20 | 20 | 20 | 20 | 50 | 20 | 10 | 10 | |
Number of the contact | 3P+NO | ||||||||||
3P+NC |